1. 查詢一般Router/Switch設備的型號與序號
#show inventory
(這邊會顯示設備的機型跟序號)
NAME: "2811 chassis", DESCR: "2811 chassis"
PID: CISCO2811 , VID: V07, SN: FTX1226A1WN
(這邊會顯示安裝的模組名稱/安裝位置/型號/序號)
NAME: "WAN Interface Card - Serial 2T on Slot 0 SubSlot 0", DESCR: "WAN Interface Card - Serial 2T"
PID: WIC-2T= , VID: 1.0, SN: 17253347
2. 查詢模組類型Router/Switch設備的型號與序號,如7200,4500,6500
#show module
(這邊會顯示安裝的 "主" 模組名稱/型號/序號)
Mod Ports Card Type Model Serial No.
--- ----- -------------------------------------- ------------------ -----------
3 48 CEF720 48 port 1000mb SFP WS-X6748-SFP SAL10421C0W
5 2 Supervisor Engine 720 (Active) WS-SUP720-3B SAL10330NGA
7 48 48-port 10/100/1000 RJ45 EtherModule WS-X6148A-GE-TX SAL51392UH6
(這邊會顯示模組的MAC位址範圍/硬體版本/韌體版本/軟體版本/狀態)
Mod MAC addresses Hw Fw Sw Status
--- ---------------------------------- ------ ------------ ------------ -------
3 0018.b98c.c514 to 0018.b98c.c543 1.8 12.2(14r)S5 12.2(18)SXF5 Ok
5 0017.9441.b3c4 to 0017.9441.b3c7 5.2 8.4(2) 12.2(18)SXF5 Ok
7 0019.55b4.2140 to 0019.55b4.216f 1.5 8.4(1) 8.5(0.46)RFW Ok
(這邊會顯示主模組上的 "次" 模組名稱/型號/序號/硬體版本/狀態)
Mod Sub-Module Model Serial Hw Status
---- --------------------------- ------------------ ----------- ------- -------
3 Centralized Forwarding Card WS-F6700-CFC SAL52457H6F 3.0 Ok
5 Policy Feature Card 3 WS-F6K-PFC3B SAL12860MU2 2.3 Ok
5 MSFC3 Daughterboard WS-SUP720 SAL14460L8Y 2.5 Ok
(這邊會顯示主模組的狀態)
Mod Online Diag Status
---- -------------------
3 Pass
5 Pass
7 Pass
沒有留言: